Other Backup Power Supplies_HS001B-RBA
  • 54.4 V High-Voltage Platform
  • Approx. 120 Wh Backup Energy
  • 44 A High-Rate Output
  • −20°C to +60°C Wide-Temperature Discharge
产品详情
Other Backup Power Supplies_HS001B-RBA
The battery uses CC/CV charging with a charge limit voltage of 63.75 V, a standard charging current of 1.1 A, and a maximum charging current of up to 2.2 A. The standard discharge current is 1.1 A, while the maximum discharge current reaches 44 A (20C), providing strong transient power output for backup power applications such as power-failure switching, equipment startup, and short-duration high-load operation.

Product Specifications & Configuration
Battery Model: HS001B-RBA
Cell Type / Capacity: JGPFR18650/1100mAh/3.2V
Battery Configuration: The finished battery pack consists of 34 cells in a 17S2P configuration and a BMS protection board.

Basic Performance
No. Item Parameter Remarks
1 Capacity Typ.2200mAh 0.2C Discharge
Min.2100mAh
2 Nominal Voltage 54.4V  
3 Charge Cut-off Voltage 63.75V  
4 Discharge Cut-off Voltage 42.5V  
5 Charging Method CC-CV  
6 Standard Charging Current 1100  mA 0.5C
7 Standard Discharge Current 1100  mA 0.5C
8 Maximum Charging Current 2200mA  
9 Maximum Discharge Current 44000mA 2000W&2.5Mins
1800W&3.0Mins
10 Operating Temperature Charging 0°C~+45°C  
Discharging -20°C~+60°C  
11 Battery Internal Resistance ≤ 340mΩ  
12 Battery Weight 3500g About
13 Battery Dimensions Length 340±2mm  
Width 110±2mm  
Thickness 100±2mm  
产品特点

High-Voltage Platform: Uses a 17S2P configuration with a nominal voltage of 54.4 V, suitable for high-voltage applications such as industrial equipment, communication terminals, and emergency power systems.

High-Rate Discharge Capability: Supports a maximum discharge current of up to 44 A (20C), meeting the power demands of equipment startup, power-failure switching, and short-duration high-load operation.

Stable Backup Power: Provides approximately 120 Wh of energy reserve, delivering continuous and stable backup power to critical loads when the main power supply is abnormal or interrupted.

Wide-Temperature Operation: Supports discharge from −20°C to +60°C and charging from 0°C to +45°C, making it suitable for a wide range of industrial and communication equipment operating environments.